If you have identified a failed, or failing disk, it is possible to replace it using the MegaCli utility. In the example below we will cover replacing a failed disk from a raid 5 that has three disks total. The first thing we want to check is the status of our raid 5. root@raid log# MegaCli64.

Pd Missing Backplane Slot 0

  1. root@ceph-aio-1:/home/campgareth# megacli -AdpAllInfo -aAll
  2. Adapter #0
  3. Serial No : SP03017026
  4. Rework Date : 00/00/00
  5. Battery FRU : N/A
  6. Image Versions in Flash:
  7. Boot Block Version : R.2.3.15
  8. MPT Version : MPTFW-01.18.172.00-IT
  9. WebBIOS Version : 1.1-33j-e_11-Rel
  10. Preboot CLI Version: 01.00-011:#%00001
  11. Pending Images in Flash
  12. None
  13. PCI Info
  14. Controller Id : 0000
  15. Device Id : 0411
  16. SubDeviceId : 1008
  17. Host Interface : PCIE
  18. Link Speed : 0
  19. Device Interface : PCIE
  20. Number of Backend Port: 16
  21. 0 0000000000000000
  22. 2 0000000000000000
  23. 4 3f535c157ba86c7e
  24. 6 3d53471ca1966ba6
  25. 8 3f535c149a9b6c7e
  26. 10 0000000000000000
  27. 12 61695603a6716573
  28. 14 0000000000000000
  29. BBU : Absent
  30. NVRAM : Present
  31. Memory : Present
  32. Memory Size : 256MB
  33. On board Expander: Absent
  34. Temperature sensor for ROC : Absent
  35. Predictive Fail Poll Interval : 300sec
  36. Interrupt Throttle Completion : 50us
  37. PR Rate : 30%
  38. Check Consistency Rate : 30%
  39. Cache Flush Interval : 4s
  40. Delay Among Spinup Groups : 12s
  41. Cluster Mode : Disabled
  42. Auto Rebuild : Enabled
  43. Ecc Bucket Size : 15
  44. Restore HotSpare on Insertion : Disabled
  45. Maintain PD Fail History : Disabled
  46. Auto Detect BackPlane Enabled : SGPIO/i2c SEP
  47. Use FDE Only : No
  48. Security Key Failed : No
  49. Default LD PowerSave Policy : Controller Defined
  50. Maximum number of direct attached drives to spin up in 1 min : 0
  51. Any Offline VD Cache Preserved : No
  52. Disable Online Controller Reset : No
  53. Use disk activity for locate : No
  54. BIOS Error Handling : Pause on Errors
  55. Capabilities
  56. RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, SRL 3 supported
  57. Mix of SAS/SATA of HDD type in VD Allowed
  58. Status
  59. ECC Bucket Count : 0
  60. Limitations
  61. Max Arms Per VD : 32
  62. Max Arrays : 128
  63. Max Parallel Commands : 1008
  64. Max Data Transfer Size : 8192 sectors
  65. Max LD per array : 16
  66. Max Strip Size : 1.0 MB
  67. Current Size of CacheCade : 0 GB
  68. Degraded : 0
  69. Physical Devices : 7
  70. Critical Disks : 0
  71. CC Rate : Yes
  72. Reconstruct Rate : Yes
  73. Alarm Control : Yes
  74. BBU : Yes
  75. Dedicated Hot Spare : Yes
  76. Foreign Config Import : Yes
  77. Allow Mixed Redundancy on Array : No
  78. Deny SCSI Passthrough : No
  79. Deny STP Passthrough : No
  80. Snapshot Enabled : No
  81. Support PFK : No
  82. Support Boot Time PFK Change : No
  83. Support Shield State : No
  84. Write Policy : Yes
  85. Access Policy : Yes
  86. Reconstruction : Yes
  87. Deny CC : No
  88. Enable LDBBM : No
  89. Power Savings : No
  90. Supported PD Operations
  91. Force Online : Yes
  92. Force Rebuild : Yes
  93. Deny Force Good/Bad : No
  94. Deny Clear : No
  95. Support Temperature : No
  96. Disable Copyback : No
  97. Enable Copyback on SMART : No
  98. Enable SSD Patrol Read : No
  99. Error Counters
  100. Memory Correctable Errors : 0
  101. Cluster Active : No
  102. Default Settings
  103. Phy Polarity : 0
  104. Background Rate : 30
  105. Flush Time : 4 seconds
  106. Read Policy : None
  107. Cached IO : Yes
  108. Alarm Disable : Yes
  109. ZCR Config : Unknown
  110. BIOS Continue on Error : 0
  111. Allowed Device Type : SAS/SATA Mix
  112. Allow HDD SAS/SATA Mix in VD : Yes
  113. Allow HDD/SSD Mix in VD : No
  114. Max Chained Enclosures : 3
  115. Enable Web BIOS : Yes
  116. BIOS Enumerate VDs : No
  117. Expose Enclosure Devices : Yes
  118. Disable Puncturing : No
  119. PreBoot CLI Enabled : Yes
  120. Cluster Disable : Yes
  121. Auto Detect BackPlane Enable : SGPIO/i2c SEP
  122. Enable Led Header : No
  123. EnableCrashDump : No
  124. EnableLDBBM : No
  125. Treat Single span R1E as R10 : No
  126. Power Saving option : All power saving options are enabled
  127. Enable JBOD : No
  128. root@ceph-aio-1:/home/campgareth# megacli -PDList -aAll
  129. Adapter #0
  130. Enclosure Device ID: 252
  131. Drive's position: DiskGroup: 0, Span: 0, Arm: 0
  132. Device Id: 29
  133. Sequence Number: 2
  134. Other Error Count: 2
  135. Last Predictive Failure Event Seq Number: 0
  136. Non Coerced Size: 1.818 TB [0xe8d088b0 Sectors]
  137. Sector Size: 0
  138. Device Firmware Level: ABB0
  139. Successful diagnostics completion on : N/A
  140. Connected Port Number: 4(path0)
  141. Inquiry Data: 15MYB3THSTOSHIBA DT01ACA200 MX4OABB0
  142. FDE Enable: Disable
  143. Locked: Unlocked
  144. Foreign State: None
  145. Link Speed: Unknown
  146. Drive Temperature : N/A
  147. Drive is formatted for PI information: No
  148. Port-0 :
  149. Port's Linkspeed: Unknown
  150. Slot Number: 6
  151. Enclosure position: N/A
  152. WWN:
  153. Media Error Count: 0
  154. Predictive Failure Count: 0
  155. PD Type: SATA
  156. Raw Size: 1.999 TB [0xffffffff Sectors]
  157. Coerced Size: 1.999 TB [0xffe18000 Sectors]
  158. Firmware state: Online, Spun Up
  159. Shield Counter: 0
  160. SAS Address(0): 0x3d53471ca1966ba6
  161. Inquiry Data: Y3MDHYBGSTOSHIBA DT01ACA300 MX6OABB0
  162. FDE Enable: Disable
  163. Locked: Unlocked
  164. Foreign State: None
  165. Link Speed: Unknown
  166. Drive Temperature : N/A
  167. Drive is formatted for PI information: No
  168. Port-0 :
  169. Port's Linkspeed: Unknown

Comments are closed.